This device is specifically designed for mechanical compression testing of plug and socket products. It simulates the conditions under which plugs and sockets are subjected to squeezing and heavy pressure during actual use, and tests the structural strength of the products and the compression resistance of their insulated housings in accordance with national and international standards.

It is primarily used in electrical product quality inspection laboratories, the quality control departments of plug and socket manufacturers, third-party testing organizations, and for the inspection of products entering or leaving the country.

1.2 المعايير المطبقة

Strictly in accordance with the last paragraph of Clause 10.1, Clause 24.6, and Figure 8 (IEC 60884-1:2022, the last paragraph of Clause 10.2, Figure 6, and Clause 24.6).

Apply a vertical compressive force to the plug and receptacle specimens in accordance with the pressure values and application duration specified in the standard; observe the specimens’ deformation and damage; and determine whether they meet the standard requirements.

1.3 مبادئ الاختبار

1.3.1 The Principle of Mechanical Pressure

A mechanical gravity-loading mechanism that uses a turntable to drive weights delivers a standard, constant load applied vertically to the surface of the plug and receptacle at the angle specified by the standard.

1.3.2 مبادئ الاختبار النوعي

After the force application time specified in the standard has elapsed, inspect the appearance of the plug and receptacle and determine whether their hardness and mechanical strength meet the requirements of national and international standards.

1.4 تنزيل المستندات الإلكترونية

لقد أرسلنا بالفعل روابط تحميل دليل المستخدم الإلكتروني، وشهادة المعايرة، وبطاقة الضمان، وغيرها من المستندات عبر البريد الإلكتروني عند الشحن. يُرجى تحميلها في أقرب وقت ممكن. إذا لم تستلم البريد الإلكتروني، يُرجى التواصل معنا لطلب روابط التحميل مرة أخرى.

2. احتياطات الاستخدام

2.1 متطلبات السلامة في بيئة التشغيل

Operating environment temperature: Relative humidity 45%–75%, no condensation, no corrosive gases, and no dust or airborne particles.

ضع الجهاز على طاولة عمل مستوية وثابتة، مع ترك مساحة عمل لا تقل عن 30 سم من جميع الجوانب، وأبقِه بعيدًا عن مصادر الاهتزاز.

2.2 إرشادات السلامة للمشغلين

During testing, do not insert your hands or fingers into the pressure-applying mechanism to prevent crush injuries.

يجب وضع العينات بشكل آمن لمنعها من السقوط أو القذف أثناء التحميل، مما قد يشكل خطراً على السلامة.

It is strictly prohibited to exceed the equipment’s rated load by adding weights without authorization or by forcing the loading mechanism down. Do so to prevent equipment damage and safety incidents.

3. نظرة عامة على المعدات

انظر الشكل 3-1.

رقم الهاتف ملاحظات
Handwheel: Manually control the position of the weights to start or stop the test
Detachable weights, with combinable forces of 150 N and 300 N
موضع تركيب العينة
Adjustable feet, leveling mechanism

Compression Test Device-Figure1

الرقم 3-1

4. إجراء اختبار الضغط

4.1 المعالجة المسبقة لعينات الاختبار

Samples with surface defects such as dents, cracks, or obvious deformation were excluded; none of the selected test specimens had undergone any destructive testing.

4.2 ظروف الاختبار

المقاطع القياسية درجة حرارة بيئة الاختبار قيمة قوة الضغط
GB/T 2099.1-2021، البند 10.1 40 ± 2 ° C 150 N
IEC 60884-12022، البند 10.2 35 ± 2 ° C
GB/T 2099.1-2021، البند 24.6 23 ± 2 ° C 300 N
IEC 60884-12022، البند 24.6

4.3 إجراء الاختبار

4.3.1 Clause 10.1 of GB/T 2099.1-2021 / Clause 10.2 of IEC 60884-1: 2022

The load shall be applied for 5 minutes; the specimen shall then be removed from the testing apparatus and inspected 15 minutes later. The specimen shall not deform to the extent that the dimensions specified in the relevant standard—which are intended to ensure safety—are unduly altered.

4.3.2 Clause 24.6 of GB/T 2099.1-2021 / Clause 24.6 of IEC 60884-1: 2022

See Figure 4-1. First, place the specimen in the position shown in Figure 8a) (Figure 6a) in the IEC standard) and apply the force for 1 minute. Then, place the specimen in the position shown in Figure 8b) (Figure 6b) in the IEC standard) and subject it to the same force for another 1 minute.

Fifteen minutes after the specimen is removed from the testing apparatus, it shall show no damage within the scope defined by this standard.

Compression Test Device-Figure2

الرقم 4-1

5. إجراءات ما بعد الاختبار

5.1 إعادة ضبط الجهاز

Turn the handwheel to lower the pressurized weight assembly to its lowest position to prevent the equipment from being subjected to prolonged loads when not in use.

5.2 تحضير العينة

افصل العينات التي اجتازت الاختبار وتلك التي فشلت فيه، وقم بتسميتها بوضوح، وتجنب خلطها.

5.3 تنظيف وترتيب موقع الاختبار

Use a lint-free, soft cloth to wipe dust and debris from the handwheel, weights, and the surface of the device. Do not rinse the equipment directly with water.

قم بتنظيم الأدوات والأوزان على طاولة العمل، ورتبها بدقة، ونظف أي بقايا متبقية من التجربة.

6. الصيانة والعناية الروتينية

6.1 الصيانة الدورية

Apply rust-preventive oil to the surface of the weights every three months to prevent rust; apply lubricating grease to moving parts such as brackets and handwheel shafts to prevent jamming during operation.

6.2 متطلبات فترة المعايرة

لضمان دقة الجهاز وموثوقيته، يُنصح بإرساله دوريًا إلى مختبر قياسات معتمد تابع لجهة خارجية لإجراء المعايرة. يُوصى بإجراء المعايرة كل 12 شهرًا. ويمكن للمستخدمين تحديد فترة المعايرة المناسبة بناءً على وتيرة الاستخدام والظروف البيئية ومتطلبات نظام الجودة.

7. استكشاف الأخطاء وإصلاحها وحل المشكلات الشائعة

أعراض الخلل الأسباب المحتملة العملية
The stand moves jerkily when raising or lowering it Dust buildup on the slide rails, insufficient lubrication, foreign objects lodged in the rails حاول مرة أخرى بعد إزالة الغبار من قضبان الانزلاق، وتجديد مادة التشحيم، وإزالة أي أجسام غريبة من الفجوات.
إزاحة القوة والإمالة The device is not level, and the weights are not properly positioned. Ensure the device is level; verify that all weights are properly positioned and not misaligned.